Creating your own Labels
In addition to the default label list, you may design your own. The process to enter the Source Label Assign
menu is the same as above, but instead of selecting one of the default labels, scroll pass the default labels and
tap the header called ‘Edit Labels’. Below this header, you will see an additional 32 user labels that may be
customized to your liking.
- Hitting the ‘Edit Label’ header will bring up the keyboard and allow you to enter your desired label.
- Once satisfied, tap the label position that you want to carry the new name and hit ‘Done’ – this will save
the new label as well as attach it to the source that you started out with.
- Hit ‘Quit’ to leave the Keyboard
- Hit the left side of the Top Menu bar to Exit.
3 - Type selection Defining the role of your
source
As mentioned earlier, the selection of the correct type or role of a specific source, is
essential to the automated routing of the source signal.
An example of why that is:
If your incoming source is defined as a ‘R’ right channel type, the PAM PICO TOUCH
automatically knows that this source needs to be routed onto the Phase correlation
meter, the StarFish Right channel input as well as the Loudness measurement block and
the Downmix module.
In case the type was changed to Ls, the PAM PICO TOUCH would not only change
inputs on the various other metering, but also make sure to compensate gain when
calculating Loudness as per the BS1770 standard Loudness definition.
The Bargraph Options menu gives access to a lot of different bargraph parameters that
we will get to a bit later. For now, let’s make sure that the Type is set correctly.
Touch the Bargraph to access the Bargraph
Options Menu