Dorrough 40-A Specifications Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 43
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
Graphical LEQ
View
The Graphical LEQ view allows
for several different
simultaneous views.
On top of the four standard text
readouts and phase meter, it
features level Bargraphs
adhering to the defined scale,
while the dual Loudness bars
are referring to the defined
loudness scale. In essence, this
means that two independent
scales are viewed at the same
time.
Furthermore, the Loudness level
is plotted against time as a
graphical track on screen,
allowing for a historical view.
Loudness may also be logged via the PiCo Logging application against either internal time or external SMPTE
timecode (free of charge).
Additionally, four extra text readouts may be defined on the top right section of the screen.
FFT 1024 View
The FFT view, simply features a
1024 band FFT spectrum
analyzer.
The FFT analyzer may be used
to check the spectral content of
individual channels in great
detail. This allows to check for
unwanted noise signals, high
and low, as well as review the
spectral balance of your source
signal.
The FFT features detailed cursor
and Zoom functions allowing
ultra high precision spectral
review.